Page 8 - DETECTORS, POWER SUPPLY UNITS and accessories
P. 8
GLASS BREAK DETECTORS GD 300 SERIES
GD 335 Glass Break Detector, Glued
Technical Data
Coverage 2 m radius (standard 4-6 mm glass)
EN 50131-2-7-2:2013 Grade 2,
VdS G 192532, Class B,
Approvals
SBSC 10-32, Class 1/2,
FG
The GD 335 is a glass break detector with transistor output that is connected to a Supply voltage 5-15 VDC, polarization-independent
control panel via an IU 300 interface unit. It is especially designed for monitoring Current consumption 5 μA (7 mA in alarm state)
shop windows, sliding glass doors, ordinary windows and other exposed glass surfa- Alarm output Transistor output
ces, both in public spaces and private homes. Alarm indication LED
It can be used on windows with protective film if the detector is mounted directly onto Tamper protection Yes
the glass and not on the film (a 5-10 cm hole must be cut out the film). It can also Alarm hold time Latching
be used on glass cabinets to protect various types of equipment. Alarm reset Power down
Connection Cable
The GD 335 glass break detector is activated when the glass is shattered or broken Housing material, Colour ABS plastic, White
and is highly resistant to interference with the glass or in its immediate environment, Operating temperature range -40 to +70°C
which makes it ideal for 24-hour monitoring. Housing protection class IP 67
Dimensions (H x Ø) mm 11 x 27
Its circular design guarantees correct positioning.
The GD 335 is glued to the glass pane and each detector is supplied with a stencil Ordering Information
to mark the mounting location, a glue applicator and cable clamps for quick and easy Model Description
installation. GD 335 Glass break detector with transistor output, glued, 3 m cable
GD 335-6 Glass break detector with transistor output, glued, 6 m cable
For laminated and tempered glass please use GD 370 or 375. GD 335-10 Glass break detector with transistor output, glued, 10 m cable