Page 7 - DETECTORS, POWER SUPPLY UNITS and accessories
P. 7
GLASS BREAK DETECTORS GD 300 SERIES
GD 330-S Glass Break Detector, Glued
Technical Data
Coverage 2 m radius (standard 4-6 mm glass)
EN 50131-2-7-2:2013 Grade 2,
VdS G 192531, Class B,
Approvals
SBSC 10-31, Class 1/2,
FG
Supply voltage 8-15 VDC
Current consumption 5 mA (17 mA in alarm mode)
Alarm output Relay, NC
Contact rating 48 VDC / 100 mA
Alarm indication LED
Tamper protection Yes
Alarm hold time Latching
Alarm reset Power down
Connection Cable / Screw terminals
Housing material, Colour ABS plastic, White
Operating temperature range- -40 to +70°C
Housing protection class IP 67
Dimensions (H x Ø) mm 16 x 35
Dimensions box (L x W x H) mm 91 x 31 x 23
The GD 330-S has the same features as the GD 330 with relay output and can be
directly connected to a control panel via the junction box JB 103-6.
Ordering Information
The detector has a coiled cable with modular connector that plugs into the junction Model Description
box JB 103-6, which allows it to be quickly and easily disconnected from the detec- GD 330-S Glass break detector with relay output, glued, coiled cable
tor loop when, for example, cleaning windows. with 6-pin modular connector plug
GD 330-SJ Glass break detector with relay output, glued, coiled cable
For laminated and tempered glass please use GD 370-S or 375-S. with 6-pin modular connector plug and junction box JB 103-6
5