Page 5 - DETECTORS, POWER SUPPLY UNITS and accessories
P. 5

Detektorkatalog rev5 inlaga SE  14-05-21  16.12  Sida 2


                            GLUED GLASS BREAK DETECTORS




          ALARMTECH’s GD 300 series of glued glass break detectors offers reliable   GVT 500 is a simpler test unit that can be used with the glass break
          and secure detectors for monitoring panes of standard or tempered glass   detectors for standard glass, GD 330 and GD 335.
          (GD 370 and GD 375 for laminated glass) with high-level immunity to false   Installing detectors on glass
          alarms. The detectors can be installed in environments with substantial
          background noise enabling 24-hour security without complication. They   The glass break detectors must be glued directly onto an undamaged glass
          solely detect the shattering of glass and are unaffected by background   pane to ensure detection of the vibration generated inside the glass when
          noise.                                               shattered or broken. The detectable radius depends on the thickness of
                                                               the glass – the thicker the glass, the larger the radius. Standard glass of
          A piezoelectric crystal sensor identifies the vibration signal generated inside   4 mm thickness has a detectable radius of two metres from the detector.
          the glass when shattered. The detector’s electronic analyser is set to high   Detectors can be used with a maximum glass thickness of 6.4 mm, which
          frequency in order to distinguish external disturbances from actual glass   extends the detection range to an approximate four-metre radius. When
          breakage. The detector is easy to install and does not require maintenance.  mounting on glass surfaces that are covered in protective film, the detector
          GD 330 and GD 370 have a built-in relay, which is powered and can be   should be mounted directly on the glass pane, not on the protective film.
          used directly via a detector loop.                   Consequently, when installing detectors on windows covered in protective
          GD 335 and GD 375 have a transistor output with power disabled in   film, a 5–10 cm hole must be cut out the film. Over time, window panes
          standby mode. These detectors must be connected to the interface unit IU   are exposed to changes in temperature and humidity as well as UV
          300 or directly via a detector loop especially suited to this type of detector.  radiation. It is therefore very important to use the recommended adhesive
                                                               during installation and ensure the gluing process is undertaken according
          For laminated glass                                  to instruction to guarantee detection capability.

          GD 370 and GD 375 are for use with laminated glass as well as all other   The adhesive kit GDK 100 has successfully been used over the past 20
          types of glass.                                      years, since production of the detector series first started. The glue has
                                                               proved resistant to the environmental impacts of temperature, humidity and
          Test Units
                                                               UV rays as well as the effects of cleaning products.
          GVT 5000 is an advanced glass breakage tester, which replicates the
          acoustic signals generated when a glass pane is shattered or broken.
   1   2   3   4   5   6   7   8   9   10