Page 15 - DETECTORS, POWER SUPPLY UNITS and accessories
P. 15

GLASS  BREAK DETECTORS GD  300 SERIES



           IU 370 Interface unit for GD 330 and GD 370








                                                                 Technical Data
                                                                  Supply voltage              9–15 VDC
                                                                  Current consumption         16 mA (19 mA in alarm state)
                                                                  Alarm output                Relay, NC
                                                                  Contact rating              48 VDC / 100 mA
                                                                  Alarm indication            LED
                                                                  Tamper protection           Yes
                                                                  Alarm hold time             2 sec / Latching
                                                                  Alarm reset                 Power down / Remotely / Manual
                                                                  Connection                  Screw terminals
                                                                  Housing material, Colour (IU 300)  ABS plastic, White
           The IU 370 is an analyser and relay unit, used to connect the GD 330 and GD 370
           glass break detectors to a control panel. Up to 10 detectors can be connected to the   Housing material, Colour (IU 300-M)  Metal, Grey
                                                                  Operating temperature range
                                                                                              -40 to +70°C
           device.                                                Housing protection class    IP 41
           IU 370 monitors resistance changes in a balanced circuit. It is possible to program it   Dimensions (L x W x H) mm  92 x 31 x 23
           for either manual reset (Latch) or auto-reset after two seconds.
           Note: An alarm from a single detector activates the alarm relay on the unit  Ordering Information
                                                                  Model     Description
                                                                  IU 370    Analyser unit for GD 330 / GD 370, white plastic housing
                                                                  IU 370-M  Analyser unit for GD 330 / GD 370, grey metal housing

                                                                                                                     13
   10   11   12   13   14   15   16   17   18   19   20