Page 12 - DETECTORS, POWER SUPPLY UNITS and accessories
P. 12

GLASS  BREAK DETECTORS GD  300 SERIES



        GD 375 Glass Break Detector for Laminated Glass, Glued







                                                              Technical Data
                                                                Coverage                    2 m radius (standard 4-6 mm glass)
                                                                Approvals                   - -
                                                                Supply voltage              5-15 VDC
                                                                Stabilizing time            10 sec.
                                                                Current consumption         5 μA (7 mA in alarm state)
         GD 375 is a passive glass break detector glued on to the glass surface. Together with   Alarm output   Transistor output
         interface IU 300 it forms a Grade 2 security system according to EN 50131-2-7-2   Alarm indication  LED
         to detect an attack against float glass through smashing with blunt force or cutting   Tamper protection  Yes
         or drilling with diamond tools. Application areas are shop-windows, glass sliding   Alarm hold time  Latching
         doors, standard windows and other vulnerable glass surfaces in public areas and   Alarm reset  Power down
         private homes.                                         Connection                  Cable
                                                                Housing material, Colour    ABS plastic, White
         It is equipped with a piezoelectric sensor that provides an electrical signal when the   Operating temperature range  -40 to +55°C
         glass is attacked. The signal is digitized and then processed in an electric circuit,   Housing protection class  IP 67
         which increases the current in the loop. With a first-rate detector algorithm, the de-  Dimensions (H x Ø) mm  11 x 27
         tector has exceptionally high immunity to interference signals that cause false alarms.
         Its circular design guarantees correct positioning.    Ordering Information
                                                                Model    Description
         The GD 375 is glued to the glass pane and each detector is supplied with a stencil   GD 375  Glass break detector for laminated glass with transistor output, glued, 3 m cable
         to mark the mounting location, a glue applicator and cable clamps for quick and easy   GD 375-6  Glass break detector for laminated glass with transistor output, glued, 6 m cable
         installation.                                          GD 375-10  Glass break detector for laminated glass with transistor output, glued, 10 m cable
      10
   7   8   9   10   11   12   13   14   15   16   17